&GS-32CT

GS-30CT
Close Tolerance Geophone

The GS-30CT represents the ultimate refinement in
geophone design to date. This new geophone is
offering heretofore unattainable geophone-to-geophone
uniformity, distortion reduced by a factor of 2.5 and
tighter tolerance on geophone parameters:

New standard ± 2%

Channel-to-channel uniformity and elimination of
self-generated noise and distortion is the essence of
seismic data. Towards this end, the performance of the
GS-30CT is clearly unsurpassed. It is a field-proven
match for the most advanced 24-bit Data
Acquisition Systems.
3 Year Warranty

GS-30CT Specifications
Specifications calculated at 25°C. Orientation is Vertical to 20°. Maintains all specifications at Vertical to 20° tilt. Exception: Harmonic Distortion at 12 Hz (Vertical only).
Frequency
Natural Frequency (Fn): 10 Hz ± 2%
Typical Spurious Frequency: > 160 Hz
Resistance
Standard Coil Resistance: 395 ohms ± 2%
Distortion
Harmonic distortion with coil to case velocity of 0.7 in/sec (1.8 cm/sec) @ 12 Hz and coil to case displacement of 0.0093 in (0.0236 cm) P-P @ 12 Hz <0.08%
With coil to case displacement of 0.0093 in (0.0236 cm) P-P @ 12 Hz <0.12%
Sensitivity
Intrinsic Voltage Sensitivity (G): .698 V/in/s, .275 V/cm/s
Sensitivity @ 70% Damping .500 V/in/sec)
(.197 V/cm/sec)± 2%
Normalized Transduction Constant: .0351 sq.root of DCR; V/in/s .0138; sq.root of DCR; V/cm/s
Damping
Open Circuit Damping (Bo) .316
Shunt Resistance for Damping Calibration for 395 ohm coil: 60% damping ± 2%: 1500 ohms
70% damping ± 2%: 1000 ohms
Damping Constant (BcRt) 536
Physical Specifications
Moving Mass (M) .395 oz., 11.2 g ± 2%
Case to Coil Motion P-P: .060 in (.152 cm)
Operating and Storage Temperature: -45°C to +100°C
Dimensions (less terminals*)
   Height 1.30 in (3.30 cm)
   Diameter 1.00 in (2.54 cm)
   Weight 3.03 oz (86 g)
* terminal height is .16 in (.41 cm)
Cases Available:
PC-801-LP Land Case
PC-801-LPC Land Case
PC-901-LP Marsh Case
Specifications are subject to change without notice.

Click HERE to load chart for Seismic Detector Response Curve Output VS. Frequency.
(115 KBytes)


GS-32CT Geophone
Close Tolerance
High Spurious Geophone


»   Spurious response greater than 250 Hz for extended clean band width
»   Full compatibility with GS-20DX and GS-30CT geophones
»   Typical string distortion less than .03% (12 series, damped .70)
»   High sensitivity option available
»   3-Year Warranty

GS-32CT Specifications
Maintains all specifications at vertical to 20° tilt with the following exception: Harmonic distortion at 12 Hz (vertical to 10° tilt).
Description Specification @ 25° C TOL ±
Natural Frequency (Fn): 10 Hz 2.5%
Coil Excursion P-P > .040 in, > .102 cm MIN
> .060 in, > .152 cm MAX
Clean Band Pass (Spurious Response) > 250 Hz (Typical)
DC Resistance (DCR) 395 ohms 2.5%
Intrinsic Voltage Sensitivity (G) .698 V/i/s, .275 V/cm/s
Open Circuit Damping (Bo) .316
Damping w/1000 ohm Shunt .70 2.5%
Sensitivity @ 70% Damping .500 V/in.s, .197 V/cm/s 2.5%
Moving Mass (M) .395 oz., 11.2 g 2.5%
Harmonic Distortion
With coil to case velocity of 0.7 in/sec (1.8 cm/sec) P-P @ 12 Hz <0.10%
String, 12 series, damped 0.70 <0.03% (Typical)
With coil to case displacement of 0.0093 in (0.0236 cm) P-P @ 10 Hz <0.20%
Dimensions
   Weight 3.03 oz., 86 g
   Diameter 1.00 in., 2.54 cm
   Height (less stud & terminals) 1.30 in., 3.30 cm
Specifications are subject to change without notice.

Click HERE to load chart for Seismic Detector Response Curve Output VS. Frequency.
(115 KBytes)



© Copyright GeoSpace, LP - Website by  Syntropy Properties, Inc. All Rights Reserved
Find Our Products Listed On Netspotz™ - The EZ Search Engine