| HS-1
Specifications |
| SPECIFICATION at
25°C, Geophone in designated operating position (Vertical or
Horizontal) |
| Natural Frequency (Fn) |
4.5 ± .75
Hz |
7.5 ± .75
Hz |
10 ± 1.0
Hz |
| DC Coil
Resistance (DCR), ohms |
225 ± 13 |
510 ± 27 |
1250 ± 62 |
225 ± 13 |
510 ± 27 |
1250 ± 62 |
225 ± 13 |
510 ± 27 |
1250 ± 62 |
| Sensitivity (G), ± 10% V/in/s |
.510 |
.718 |
1.15 |
.510 |
.718 |
1.15 |
.510 |
.718 |
1.15 |
| Sensitivity (G), ± 10% V/cm/s |
.201 |
.283 |
.453 |
.201 |
.283 |
.453 |
.201 |
.283 |
.453 |
| Open Circuit Damping (Bo), ± 20% |
.27 |
.28 |
.28 |
.62 |
.67 |
.67 |
.46 |
.50 |
.50 |
| Damping
Constant (CD) |
246 |
505 |
1295 |
334 |
718 |
1843 |
251 |
539 |
1382 |
| Coil Mass (M), grams ± 5% |
29 |
28 |
28 |
12.8 |
11.8 |
11.8 |
12.8 |
11.8 |
11.8 |
| Maximum Tilt Angle |
Vertical Models Horizontal
Models
|
15° ± 2°
 |
Vertical Models Horizontal
Models
|
20° ± 3.5°
 |
Vertical Models Horizontal
Models
|
30° ± 7.5°
 |
| Coil/Case Displacement in operating position, peak to
peak |
Minimum .05 in (.13 cm),
Maximum .10 in (.25 cm) |
 |
 |
| Natural Frequency (Fn) |
15 ± 1.0
Hz |
20 ± 1.0
Hz |
28 ± 1.4
Hz |
| DC Coil
Resistance (DCR), ohms |
225 ± 13 |
510 ± 27 |
1250 ± 62 |
225 ± 13 |
510 ± 27 |
1250 ± 62 |
225 ± 13 |
510 ± 27 |
1250 ± 62 |
| Sensitivity (G), ± 10% V/in/s |
.510 |
.718 |
1.15 |
.510 |
.718 |
1.15 |
.510 |
.718 |
1.15 |
| Sensitivity (G), ± 10% V/cm/s |
.201 |
.283 |
.453 |
.201 |
.283 |
.453 |
.201 |
.283 |
.453 |
| Open Circuit Damping (Bo), ± 20% |
.31 |
.33 |
.33 |
.23 |
.25 |
.25 |
.16 |
.18 |
.18 |
| Damping
Constant (CD) |
167 |
359 |
922 |
125 |
269 |
691 |
89.5 |
192 |
494 |
| Coil Mass (M), grams ± 5% |
12.8 |
11.8 |
11.8 |
12.8 |
11.8 |
11.8 |
12.8 |
11.8 |
11.8 |
| Maximum Tilt Angle |
Vertical Models Horizontal
Models
|
60° ± 30°
 |
All Models |
90° ± 3.5°
 |
All Models |
90° ± 3.5°
 |
| Coil/Case Displacement in operating position, peak to
peak |
Minimum .07 in (.18 cm),
Maximum .10 in (.25 cm) |