HS-1
Geophone

Geo Space has been manufacturing inertial sensors since 1957 and has high quality, low cost geophones for a variety of industrial uses. The HS-1 geophones have an unlimited shelf life and give years of trouble-free service in applications where accurate motion sensing is needed.
The HS-1 is an integral component in the monitoring and analysis of machinery vibration. This rugged, self-generating velocity sensor converts mechanical motion into an electrical signal which is proportional to relative velocity. The HS-1 dual-coil construction minimizes interference from electromagnetic fields.
The HS-1 has natural frequencies from 4.5 to 28 Hz., with sensitivities from 460 to 1150 mV/ips. The are sensitive to motion along their longitudinal axes. Models with resonant frequency of 10 Hz or less are designed to operate in one position, either horizontal or vertical. Models with resonant frequencies of 14 Hz or higher can be oriented over a wide range of positions.

HS-1 Specifications
SPECIFICATION at 25°C, Geophone in designated operating position (Vertical or Horizontal)
Natural Frequency (Fn) 4.5 ± .75 Hz 7.5 ± .75 Hz 10 ± 1.0 Hz
DC Coil Resistance (DCR), ohms 225 ± 13 510 ± 27 1250 ± 62 225 ± 13 510 ± 27 1250 ± 62 225 ± 13 510 ± 27 1250 ± 62
Sensitivity (G), ± 10% V/in/s .510 .718 1.15 .510 .718 1.15 .510 .718 1.15
Sensitivity (G), ± 10% V/cm/s .201 .283 .453 .201 .283 .453 .201 .283 .453
Open Circuit Damping (Bo), ± 20% .27 .28 .28 .62 .67 .67 .46 .50 .50
Damping Constant (CD) 246 505 1295 334 718 1843 251 539 1382
Coil Mass (M), grams ± 5% 29 28 28 12.8 11.8 11.8 12.8 11.8 11.8
Maximum Tilt Angle Vertical Models
Horizontal Models
15° ± 2°
Vertical Models
Horizontal Models
20° ± 3.5°
Vertical Models
Horizontal Models
30° ± 7.5°
Coil/Case Displacement in operating position, peak to peak ——Minimum .05 in (.13 cm), Maximum .10 in (.25 cm) ——
Natural Frequency (Fn) 15 ± 1.0 Hz 20 ± 1.0 Hz 28 ± 1.4 Hz
DC Coil Resistance (DCR), ohms 225 ± 13 510 ± 27 1250 ± 62 225 ± 13 510 ± 27 1250 ± 62 225 ± 13 510 ± 27 1250 ± 62
Sensitivity (G), ± 10% V/in/s .510 .718 1.15 .510 .718 1.15 .510 .718 1.15
Sensitivity (G), ± 10% V/cm/s .201 .283 .453 .201 .283 .453 .201 .283 .453
Open Circuit Damping (Bo), ± 20% .31 .33 .33 .23 .25 .25 .16 .18 .18
Damping Constant (CD) 167 359 922 125 269 691 89.5 192 494
Coil Mass (M), grams ± 5% 12.8 11.8 11.8 12.8 11.8 11.8 12.8 11.8 11.8
Maximum Tilt Angle Vertical Models
Horizontal Models
60° ± 30°
All Models 90° ± 3.5°
All Models 90° ± 3.5°
Coil/Case Displacement in operating position, peak to peak ——Minimum .07 in (.18 cm), Maximum .10 in (.25 cm) ——


Click HERE to load chart for Seismic Detector Response Curve Output VS. Frequency.
(Warning: 115 KBytes)
Weight:  8.7 oz.
Temperature (Operating and Storage):  -45° C to 100°C
To order, specify Fn, DCR and (vertical or horizontal) operating position, HS-1.
Specifications are subject to change without notice.

To Top
© Copyright GeoSpace, LP - Website by  Syntropy Properties, Inc. All Rights Reserved
Find Our Products Listed On Netspotz™ - The EZ Search Engine