Leader Wire For Land and Marsh
Environments
 |
Leader Wire
Jacket: Polyurethane |
Conductors:
Tinned copper clad steel
or cadmium bronze, stranded |
Conductor
Insulator: Polypropylene |
Operating
Temperature: -50°F to +170°F
(-45°C to +75°C) |
 |
 |
 |
D-Loops: Metal, molded, or field-installable polyurethane
installed at customer specified intervals |
 |
Geo Space manufactures leader wire that provides excellent
durability in a variety of configurations. The leader wire consists of tinned
copper clad steel or cadmium bronze conductor with polypropylene insulation.
After twisting 2, 3, or 4 conductors, an all-weather jacket of polyurethane is
applied. During this process, an adhesive filler can be added for extra
protection against possible water intrusion through accidental cuts in the
outer jacket.
Geo Space's ongoing commitment to quality, along with continuous
inspection at critical points in the manufacturing process, assures a leader
wire that will provide long lasting service even in the harshest of
environments. The leader wire is available with metal, molded, or
field-installable polyurethane D-loops installed at customer specified
intervals. It can be shipped on reels or coiled in cardboard
boxes.
|
| Specifications |
| Type Number |
O.D.
Inches |
Break Strength
(lbs.) |
Weight Lb/M
ft. |
Ohms M
ft. |
Jacket Wall
Thickness In. |
O.D. MM |
Break Strength
KG |
Weight
KG/KM |
Ohms KM |
Jacket Wall
Thickness MM |
| GSC-2-70-180 |
0.180 |
140 |
16.1 |
35 |
0.039 |
1.295 |
63.5 |
24.0 |
115 |
0.991 |
| GSC-2-100-180 |
0.180 |
200 |
19.0 |
24 |
0.027 |
1.600 |
90.7 |
28.3 |
79 |
0.686 |
| GSC-3-50-180 |
0.180 |
150 |
16.5 |
50 |
0.039 |
1.219 |
68.0 |
24.6 |
164 |
0.991 |
| GSC-3-50-180 Filled |
0.180 |
150 |
16.2 |
50 |
0.039 |
1.219 |
68.0 |
24.0 |
164 |
0.991 |
| GSC-3-70-180 |
.180 |
210 |
18.2 |
35 |
0.035 |
1.295 |
95.3 |
27.1 |
115 |
0.889 |
| GSC-3-70-180 Filled |
.180 |
210 |
17.9 |
35 |
0.035 |
1.295 |
95.3 |
26.6 |
115 |
0.889 |
 |
| GSC-2-100-210 |
0.210 |
200 |
23.5 |
24 |
0.042 |
1.600 |
90.7 |
35.0 |
79 |
1.067 |
| GSC-2-100-210 Filled |
0.210 |
200 |
22.7 |
24 |
0.042 |
1.600 |
90.7 |
33.8 |
79 |
1.067 |
| GSC-3-70-210 |
0.210 |
210 |
22.7 |
35 |
0.050 |
1.295 |
95.3 |
33.7 |
115 |
1.270 |
| GSC-3-70-210 Filled |
0.210 |
210 |
22.3 |
35 |
0.050 |
1.295 |
95.3 |
33.1 |
115 |
1.270 |
| GSC-3-100-210 |
0.210 |
300 |
26.8 |
24 |
0.041 |
1.600 |
136.1 |
39.9 |
79 |
1.041 |
| GSC-3-100-210 Filled |
0.210 |
300 |
26.1 |
24 |
0.041 |
1.600 |
136.1 |
38.9 |
79 |
1.041 |
 |
| GSC-4-70-220 Filled |
0.220 |
280 |
31.5 |
35 |
0.050 |
1.295 |
95.3 |
47.0 |
115 |
1.270 |
 |
| GSC-3-100-225 |
.225 |
300 |
29.3 |
24 |
0.048 |
1.600 |
136.1 |
43.6 |
79 |
1.219 |
 |
| GSC-2-70-250 Filled |
.250 |
140 |
26.5 |
35 |
0.074 |
1.295 |
95.3 |
39.3 |
115 |
1.778 |
| GSC-3-70-250 |
.250 |
210 |
29.8 |
35 |
0.070 |
1.295 |
95.3 |
44.3 |
115 |
1.778 |
| GSC-3-70-250 Filled |
.250 |
210 |
29.4 |
35 |
0.070 |
1.295 |
95.3 |
43.7 |
115 |
1.778 |
| GSC-3-100-250 |
.250 |
300 |
33.9 |
24 |
0.061 |
1.600 |
136.1 |
50.4 |
79 |
1.549 |
| GSC-3-100-250 Filled |
.250 |
300 |
33.2 |
24 |
0.061 |
1.600 |
136.1 |
49.5 |
79 |
1.549 |
| GSC-2-150CB-310 |
.310 |
300 |
46.7 |
14 |
0.052 |
1.829 |
136.1 |
69.5 |
46 |
1.321 |
| GSC-2-225CB-310 |
.310 |
450 |
59.3 |
4 |
0.054 |
2.540 |
204.1 |
80.8 |
13 |
1.372 |
| GSC-2-225CB-310 Filled |
.310 |
450 |
52.0 |
4 |
0.054 |
2.540 |
204.1 |
77.4 |
13 |
1.372 |
| GSC-4-100-310 Filled |
.310 |
400 |
53.4 |
24 |
0.079 |
1.600 |
136.1 |
79.8 |
79 |
2.006 |
 |
| GSC-3-225-CB-360 Filled |
.360 |
675 |
74.0 |
4 |
0.076 |
2.540 |
306.2 |
110.2 |
13 |
1.930 |
| GSC-3-100-360 Filled |
.360 |
300 |
55.1 |
24 |
1.006 |
1.600 |
136.1 |
82.5 |
8 |
2.946 |
 |
| GSC-2-225CB-400 |
.400 |
450 |
78.8 |
4 |
0.099 |
2.540 |
204.1 |
117.2 |
13 |
2.515 |
| GSC-2-225CB-400 Filled |
.400 |
450 |
76.8 |
4 |
0.099 |
2.540 |
204.1 |
114.3 |
13 |
2.515 |
|
| Interpretation of Geo Space Type Numbers |
| GSC-2-50-180 |
| GSC = Geo Space
Leader |
2 = Number of conductors in
the Leader |
50 = Break Strength of Each
Conductor |
180 = O.D. over the
Polyurethane Jacket |
|
We can manufacture to
special requirements.
 Specifications are subject to change